Refrigerator COP Calculator

Find a refrigerator's coefficient of performance.

How it is calculated

This is the ideal (Carnot) coefficient of performance of a refrigerator, the upper limit any real machine can reach: COP = T_cold / (T_hot - T_cold). T_cold is the temperature of the cold space and T_hot the temperature of the surroundings it rejects heat to, both in kelvin (K = °C + 273.15). The temperatures must be absolute, T_cold above 0 and T_hot greater than T_cold, otherwise the tool returns nothing. COP is dimensionless: heat removed from the cold space per unit of work put in. A real refrigerator reaches only a fraction of this value because of friction, pressure drops and non-ideal compressors.

Worked example

A fridge interior at 275 K (about 1.85 °C) in a kitchen at 300 K (about 26.85 °C). The temperature difference is 300 - 275 = 25 K. COP = 275 / 25 = 11.00. In the ideal case, each unit of work moves 11 units of heat out of the fridge. A real unit might reach 2 to 4, so the Carnot figure is a ceiling, not a prediction.

Try this example →

Common mistakes

  • Entering Celsius values like 4 and 25. They must be converted to kelvin first, otherwise COP comes out wrong.
  • Swapping hot and cold. The hot temperature must be the larger one, or the tool returns no result.
  • Expecting the Carnot COP to match the label of a real appliance; real devices are well below it.
  • Confusing refrigerator COP with heat-pump COP. For heating the formula uses T_hot in the numerator.

About this calculator

This calculator finds the theoretical maximum coefficient of performance of a refrigerator, the Carnot COP = T_c/(T_h−T_c), where T_c and T_h are the cold and hot reservoir temperatures in kelvin. COP measures how much heat is removed from the cold space per unit of work input — a value that can exceed 1, unlike a simple efficiency ratio — and the Carnot limit represents the absolute best any refrigeration cycle could achieve between those two temperatures, a direct consequence of the second law of thermodynamics.

HVAC and refrigeration engineers use this Carnot benchmark to see how far a real refrigerator's or air conditioner's actual COP falls short (a heat pump in heating mode is compared with the related limit T_h/(T_h−T_c)) of the theoretical ceiling, which highlights where a design has room for efficiency improvement. Appliance designers use it during early-stage design to set realistic performance targets, and thermodynamics students use this calculator to connect the abstract Carnot cycle to a device they use every day.